Polyaniline nanofiber based surface acoustic wave gas sensors - Effect of nanofiber diameter on H-2 response
A. Z. Sadek, C. O. Baker, D. A. Powell, W. Wlodarski, R. B. Kaner, and K. Kalantar-zadeh,
IEEE Sensors J. 7, 213-218 (2007).
[Full-text PDF (406 Kb)]
[Online]
Abstract: A template-free rapidly mixed reaction was employed to synthesize polyaniline nanofibers using chemical oxidative polymerization of aniline. Hydrochloric acid (HCl) and camphor sulfonic acid (CSA) were used in the synthesis to obtain 30and 50-nm average diameter polyaniline nanofibers. The nanofibers were deposited onto layered {ZnO}/64 degrees YX {{LiNbO}$_3$} surface-acoustic-wave transducers. The sensors were tested toward hydrogen (H-2) gas while operating at room temperature. The dopant for the polyaniline nanofiber synthesis was found to have a significant effect on the device sensitivity. The sensor response was found to be larger for the 50-nmdiameter CSA-doped nanofiber based sensors, while the response and recovery times were faster for the 30-nm diameter HCl-doped nanofibers.
Keywords: conducting polymer; h-2 sensor; polyaniline nanofiber; rapidly mixed; surface acoustic wave (saw);; conducting polymers; chemical sensors; films; polypyrrole; morphology
Copyright © by the respective publisher.
This article may be downloaded for personal use only.
Any other use requires prior permission of the author